Volume corrector EK220 PT1000 0.8÷5 Bar
Volume corrector EK220 PT1000 0.8÷5 Bar
Volume corrector EK220 PT1000 0.8÷5 Bar
Volume corrector EK220 PT1000 0.8÷5 Bar

Volume corrector EK220 PT1000 0.8÷5 Bar

CNEK22008.5.P10
Tax included

EK220 PT1000 with Range Volume converter with datalogger function, consisting of a central unit equipped with a pressure sensor and a temperature sensor. With measurement range from 0.8÷5 Bar.

 

EK220 is a battery powered volume converter. The device detects low-frequency pulses of the gas volume measured at operating conditions from a gas meter. Measures the pressure and operating temperature of the gas, calculates the compressibility coefficient K and the conversion factor C.

Using this initial data, it is possible to calculate gas volumes at standard conditions, flow rates at standard conditions, and flow rates at operating conditions.

The volume converter consists of a central unit equipped with an integrated or external pressure sensor and a temperature sensor.

The sensors are permanently connected to the unit. The compressibility coefficient K can be programmed as a fixed value for all gases or calculated according to various methods.

Thanks to the four digital outputs, the flexibility of the data logging function in addition to the freely configurable serial interface and the availability of different communication protocols, EK220 can be used for various applications in the field of natural gas measurement and station monitoring .

Additional components for data retransmission and explosion-proof insulation of the interfaces and the intrinsically safe external power supply broaden the range of possible uses of the converter.

In addition to the conversion of gas volumes and data storage (data logging), the EK220 can be used for the flexible recording of various measured values and, in combination with a  modem or a remote data transmission unit (RTU), for system monitoring.

The device is equipped with two additional digital inputs, which can be used to record and monitor the signaling sensors, such as the safety blocking valves of the pressure regulators and the differential pressure switches of the filters, or for a simple door contact. The signals emitted by these sensors can be saved as an event in an archive and automatically retransmitted as a text message or e-mail via a connected modem.

Optionally, the volume converter can be equipped with a second external pressure sensor which allows you to detect the pressure at the input or output of the measurement system or to monitor its limit values.

Applications

Conversion of gas volumes for billing purposes

Data storage (data logging) for various applications

Monitoring of measured values and typical functions of a measuring station

Operating temperature
from -25 to + 55 ° C
Degree of protection
IP66
Measurement range
0.5÷8 Bar
Outputs Available
RS232 / RS485 modbus
Operating voltage
5 ÷ 10 Vdc Lithium battery
Process attack
Threaded M12 x 1.5
Certificates and Approvals
MID Approval, IECEx Certification, ATEX Declaration, CE Declaration of Conformity